PhD THESIS DEFENSE PRESENTATION / DEPARTMENT OF INTERIOR ARCHITECTURE AND ENVIRONMENTAL DESIGN
Thesis Title: Development of a Multi-Criteria Decision-Support Methodology for Integrated Energy-Seismic Life Cycle Cost Evaluation of Exterior Wall Configurations
by
Beyza Yazıcı
Advisor: Prof. Dr. Yasemin Afacan
Co-Advisor: Prof. Dr. Oğuzhan Hasançebi
Date: Tuesday, November 24, 2026
Time: 10:30 AM
Place: FADA, Dean’s Office Meeting Room (FDZ-09)
Abstract: In order to improve the performance of the residential buildings, the energy efficiency and the seismic resilience should be considered comprehensively in the framework of a life cycle cost (LCC). This thesis proposes a generic multi-criteria decision-support methodology to assess the LCC performance of exterior wall configurations (EWCs) for mid-rise reinforced-concrete (RC) residential buildings. The methodology involves analytical thermal transmittance (U-value) calculations, DesignBuilder-based energy simulations and LCC analysis to jointly evaluate the operational energy and carbon costs, initial construction costs and expected seismic repair costs over the building life cycle. A representative case study for residential buildings in Türkiye is proposed to demonstrate and validate the proposed framework. The six climate zones in Türkiye have been grouped into three climate categories based on (i) the U-value limits specified in the thermal insulation requirements (TS 825:2024), (ii) overlapping market-standard recommended minimum insulation thicknesses, and (iii) availability of the insulation materials in discrete thicknesses listed in the 2025 Construction and Installation Unit Price List published by the Ministry of Environment, Urbanization, and Climate Change. 36 baseline EWCs were developed for each category, using combinations of alternative masonry units, insulation materials and exterior finishes. Then, a screening based on Pareto-optimality analysis was performed to determine the EWCs that offer the best compromise between unit construction cost and thermal transmittance, resulting in the identification of eight configurations. These configurations were evaluated in the climatic regions where they comply with the criteria of national thermal standards, spanning all four seismic design categories outlined by national seismic standards. This yields 144 climate-seismic EWC scenarios. The results indicate that the lowest unit construction cost of EWCs results in the lowest LCC, highlighting the significance of unit construction cost in the early stages of decision-making.